16. INSTRUMENT/SWITCHES/LIGHTS ZX / SCOUT 50
INSTALLATION
The installation sequence is the reverse of
removal.
Retainer
OIL METER
INSPECTION
Remove the met-in box. ( 12-4) Oil Meter
G/R B
Remove the frame body cover. ( 12-4) G G
Disconnect the oil meter wire connectors B
and remove the oil meter. Keep the oil
meter float at the lower position.
Measure the resistances between the wire
terminals as and shown in the left
figure.
Wire Terminals Resistance
Float
Green/Red(+)Black(-) 516
Green(-)Black(+)
Oil Meter Operation Inspection
Connect the oil meter wire connectors and
turn the ignition switch ON.
Measure the resistance between the wire
terminals with the float at upper position.
Light OFF
Green/Red(+)Black(-) About 340
4.51.0mm
Light ON
16-3