          15. ELECTRICAL EQUIPMENT                                                    ZX / SCOUT 50


 CDI UNIT INSPECTION
 Remove the battery cover.                       Coupler
 Disconnect the CDI coupler and remove the
 CDI unit.




 CDI CIRCUIT INSPECTION                            CDI Unit
 Measure the resistance between the
 terminals.                                            Black/      Black/    Black/
 Replace the CDI unit if the readings are not          White       Red       Yellow
 within the specifications in the table below.




                                                                Green           Blue/Yellow
 Use the x K range for the Sanwa Tester.
 Use the x 100 range for the Kowa Tester.

                                   Unit: K
    Probe
            Black/ Black/ Black/ Blue/ Green
 (-)Probe   Yellow Red White Yellow
 Black/
                                           
 Yellow
  Black/
                          1~10             
   Red
  Black/
                                           
  White
  Blue/
                   3~40 80~120           10~30
 Yellow

  Green            2~10 10~30      


                                                                                      15-10