mxer mxu 150 Workshop-manual : Page 213

Microfiches
Image preview

Page 211

Image preview

Page 212

Image preview

Page 214

Image preview

Page 215

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 244
          14. BATTERY/CHARGING SYSTEM/
     A.C. GENERATOR                                                                     ATV 150/125

                                                  Regulator/Rectifier
REGULATOR/RECTIFIER
MAIN HARNESS CIRCUIT INSPECTION
Remove the front fender.
Remove the regulator/rectifier lock nuts and
5P coupler.




                                                                                           Lock Nut


REGULATOR/RECTIFIER INSPECTION                     Pink                Black             Green
If the main harness terminals are normal,
check the regulator/rectifier coupler for loose
connection and measure the resistance
between the regulator/rectifier terminals.
 · Do not touch the tester probes with
      your finger because human body has
      resistance.
    · Use the following specified testers for
      accurate testing. Use of an improper
      tester in an improper range may give
      false readings.                                  Red                     Yellow
      - Kowa Electric Tester
      - Sanwa Electric Tester
      - Kowa Electric Tester TH-5H                     Probe
    · Proper range for testing:                   Probe(-)     Black    Pink       Red  Yellow Green
      - Use XK range for Sanwa Tester             Black                 4-7K     13-17K 4-7K   1-2K
      - Use X100 range for Kowa Tester
                                                   Pink                           4-7K          
    · If the dry battery in the tester is weak,
      the readings will be incorrect. In this      Red                                          
      case, check the dry battery.                Yellow                          4-7K          
    · The Kowa tester readings are 100
      times the actual values. Be careful         Green 1-2K            4-6K     13-17K 4-6K
      during testing.

Replace the regulator/rectifier if the readings
are not within the specifications in the table.




                                                                                                 14-6