mxer mxu 150 Workshop-manual : Page 218

Microfiches
Image preview

Page 216

Image preview

Page 217

Image preview

Page 219

Image preview

Page 220

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 244
          15. IGNITION SYSTEM                                                               ATV 150/125


 TROUBLESHOOTING
 High voltage too low                               No high voltage
 · Weak battery or low engine speed                 · Faulty ignition switch
 · Loose ignition system connection                 · Faulty CDI unit
 · Faulty CDI unit                                  · Poorly connected or broken CDI ground wire
 · Faulty ignition coil                             ·Dead battery or faulty regulator/rectifier
 · Faulty pulser coil                               · Faulty ignition coil connector
 Normal high voltage but no spark at plug           · Faulty pulser coil
 · Faulty spark plug
 · Electric leakage in ignition secondary circuit
 · Faulty ignition coil
 Good spark at plug but engine won`t start
 · Faulty CDI or incorrect ignition timing
 · Faulty change gear control unit
 · Improperly tightened A.C. generator flywheel




15-3