12. COOLING SYSTEM MXU 300/250
Thermostat Bolts Air Vent Tube
THERMOSTAT
THERMOSTAT REMOVAL
Drain the coolant. (page 12-7)
Disconnect the thermosensor wire from the
thermosensor.
Disconnect the water hose from the
thermostat housing.
Disconnect the air vent tube from the
thermostat housing.
Remove the mounting bolt and the
thermostat housing from the cylinder head.
Water Hose
Bolts
Remove the two screws and separate the
thermostat housing halves.
Thermostat
Thermostat
Remove the thermostat from the thermostat
housing.
12-14