          8. A.C. GENERATOR                                                          VITALITY 50


 Remove the A.C. generator flywheel using
 the flywheel puller.

 Special

 Flywheel puller           E001




                                                Flywheel Puller            Lock Nut Wrench


                                               A.C. Generator Wire Connector
 Remove the A.C. generator wire connector.




 Remove the two pulser coil bolts and pulser   Stator                    Wire Clamp
 coil from the right crankcase.
 Remove the pulser coil wire clamp from the
 right crankcase.
 Remove the two bolts attaching the A.C.
 generator stator.

   Be careful not to damage the
   disconnected wire.




                                                           Pulser Coil


                                                                                        8-4