          8. A.C. GENERATOR                                                        VITALITY 50

                                                 A.C. Generator Wire Connector
 INSTALLATION
 Install the A.C. generator stator and pulser
 coil wire clamp onto the right crankcase,
 and then install the pulser coil.

 Connect the A.C. generator wire connector.




 Clean the taper hole in the flywheel off any
 burrs and dirt.
 Install the woodruff key in the crankshaft
 keyway.




                                                                    Woodruff Key


                                                     Universal Holder
 Install the flywheel onto the crankshaft with
 the flywheel groove aligned with the
 crankshaft woodruff key.
 Hold the flywheel with the universal holder
 and install the 10mm flywheel flange nut.
 Torque: 3.54.0kg-m
 Start the engine and check the ignition
 timing. ( 3-14 or 3-15)
  Special

 Universal holder           E017