          16. ELECTRICAL EQUIPMENT                                 VITALITY 50

 BATTERY INSPECTION
 Remove the battery cover and disconnect
 the battery cables.
 Measure the voltage (20°C/68°F) between
 the battery terminals.
 Fully charged : 13.0V13.2V
 Undercharged : 12.3V max.




 CHARGING METHOD
 Connect the charger positive (+) cable to
 the battery positive (+) cable.
 Connect the charger negative (-) cable to
 the battery negative (-) cable.
 · Keep flames and sparks away from a
     charging battery.
   · Turn power ON/OFF at the charger,
     not at the battery terminals to prevent
     sparks near the battery.
   · Charge the battery according to the
     current specified on the battery surface.
                                                 Black      Red
 Charging current: Standard : 0.4A
                    Quick : 4A
 Charging time : Standard : 5 ~10hours
                    Quick : 0.5 hour
 After charging: Open circuit voltage: 12.8V
 min.

 · Quick charging should only be done in
     an emergency.
   · During quick charging, the battery
     temperature should not exceed 45.
   · Measure the voltage 30 minutes after
     the battery is charged.




                                                                  16-6