16. CHARGING SYSTEM ZING125
Regulator/Rectifier
REGULATOR/RECTIFIER
REMOVAL
Remove the rear carrier and seat. (Refer to 4-
10.)
Remove the regulator/rectifier lock nut and
disconnect the regulator/rectifier wire
coupler.
Measure the resistance between the
regulator/rectifier wire terminals. Replace
the regulator/rectifier if the readings are not
within the specifications in the table below.
Coupler
Red Pink Black
· Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester or measurements in an improper
range may give false readings.
Yellow Green
Testing Range (+)Probe
Pink Yellow Red Green Black
(-)Probe
Pink 4-7K
Yellow 4-7K
Red
Green 4-6K 4-6K 13-17K 1-2K
Black 4-7K 4-7K 13-17K 1-2K
16-5