movie 125 euro 3 Workshop-manual : Page 153

Microfiches
Image preview

Page 151

Image preview

Page 152

Image preview

Page 154

Image preview

Page 155

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 211
          14. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                                MOVIE SYSTEM


 SERVICE INFORMATIONN
 GENERAL INSTRUCTIONS
   The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and
   eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and
   get prompt medical attention

 · The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
   long time, its service life will be shortened. Generally, the capacity of a battery will decrease
   after it is used for 23 years. A capacity-decreased battery will resume its voltage after it is
   recharged but its voltage decreases suddenly and then increases when a load is added.
 · When a battery is overcharged, some symptoms can be found. If there is a short circuit inside
   the battery, no voltage is produced on the battery terminals. If the rectifier won`t operate, the
   voltage will become too high and shorten the battery service life.
 · If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
   months.
 · A new battery filled with electrolyte will generate voltage within a certain time and it should be
   recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
 · Inspect the charging system according to the sequence specified in the Troubleshooting.
 · Do not disconnect and soon reconnect the power of any electrical equipment because the electronic
   parts in the regulator/rectifier will be damaged. Turn off the ignition switch before operation.
 · It is not necessary to check the MF battery electrolyte or fill with distilled water.
 · Check the load of the whole charging system.
 · Do not quick charge the battery. Quick charging should only be done in an emergency.
 · Remove the battery from the motorcycle for charging.
 · When replacing the battery, do not use a traditional battery.
 · When charging, check the voltage with an voltmeter.
 SPECIFICATIONS
                           Item                                              Standard
                       Capacity/Model                  12V-8AH
                       Voltage        Fully charged    13.1V
 Battery               (20)           Undercharged     12.3V
                       Charging current                STD: 0.9A Quick: 3.0A
                       Charging time                   STD: 510hr Quick: 30min
                       Capacity                        0.114KW/5000rpm
 A.C. Generator
                     Charging coil resistance (20) YellowPink
                     Type                          Single-phase half-wave SCR
 Regulator/Rectifier                 Lighting      12.014.0V/5000rpm (Electric tester, tachometer)
                     Limit voltage                 1013.0V/5000rpm
                                     Charging      13.515.5V/5000rpm
                     Resistance (20) 20W5.9        5.07.0
 Resistor
                     Resistance (20) 20W5.9        4.06.0




                                                                                               14-2