          16. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                  MXU 300/250


 5. Release the rings and remove the rubber
    band (6).




 6. Shift the battery (7) and the terminal
    leads face you.
 7. Disconnect the negative (-) terminal lead
    (8) from the battery first, then disconnect
    the positive (+) terminal lead (9).
 8. Remove the battery.

   When disconnecting the battery positive
   (+) cable, do not touch the frame with
   tool; otherwise it will cause short circuit
   and sparks to fire the fuel.




 INSTALLATION
 1. Installation is in the reverse order of
     removal.
   First connect the positive (+) cable and then
   negative (-) cable to avoid short circuit.

 2. Make sure the battery is installed upright
    as shown
 3. Check all bolts and other fasteners are
    secure.
 4. After installing the battery, check to see if
    the battery cables are routed correctly.




16-5