          16. ELECTRICAL EQUIPMENT                                                        VITALITY 50

                                                                Starter Relay
 STARTER RELAY INSPECTION
 Remove the met-in box. ( 13-5)

 Disconnect the starter relay coupler and
 then remove the starter relay.




                                                Red     Starter Relay (2-Stroke)     Yellow/Red
 Connect the starter relay green/yellow
 terminal to the 12V battery positive (+)
 terminal and the relay yellow/red terminal
 to the battery negative (-) terminal. Check
 for continuity between the starter relay red
 and red/white terminals. The relay is
 normal if there is continuity.




                                                  Red/White                        Green/Yellow




                                                Starter Relay (4-Stroke)




                                                                                          16-18