zing 125 qe Workshop-manual : Page 150

Microfiches
Image preview

Page 148

Image preview

Page 149

Image preview

Page 151

Image preview

Page 152

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 158
          17. STARTING SYSTEM                                                  ZING125
                                                 Wire Terminal
 STARTER MOTOR HOUSING
 CONTINUITY CHECK
 Check to confirm that there is no continuity
 between the starter motor wire terminal and
 the motor housing.
 Also check for the continuity between the
 wire terminal and each brush. There should
 be continuity.
 Replace if necessary.




 Measure the length of the brushes.
 Service Limit: 8.5mm replace if below




                                                    Brushes
 Check for continuity between the brushes.
 Replace if there is continuity.




                                                       Front Cover
 Check if the bearing in the front cover turns
 freely and has no excessive play.
 Check the oil seal for wear or damage.
 Replace if necessary.




                                                         Oil Seal

17-3