mxu 250 300 Workshop-manual : Page 96

Microfiches
Image preview

Page 94

Image preview

Page 95

Image preview

Page 97

Image preview

Page 98

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 352
          5. FUEL SYSTEM                                                           MXU 300/250


 AIR CLEANER HOUSING                               Breather Hose
 REMOVAL/INSTALLATION

 Remove the seat (see page 2-3).
 Remove the side covers (see page 2-6).

 Remove the clip and disconnect the
 crankcase breather hose from the crankcase.
 Loosen the carburetor-to-air cleaner
 connecting tube band screw.


                                                                   Band Screw




                                               Trim Clip
 Remove the intake air duct trim clip.
 Remove the mounting bolts and then remove
 the air cleaner housing from the carburetor
 and the intake duct.

 Installation is in the reverse order of
 removal.




                                                       Bolts




5-15