          15. ELECTRICAL EQUIPMENT                                                SUPER 9       50


 CDI UNIT INSPECTION                                 Coupler
 Open the front tool box and remove the bolt.
 Remove the front tool box. ( 2-4)
 Disconnect the CDI coupler and remove the
 CDI unit.




                                                        CDI Unit
 CDI CIRCUIT INSPECTION
 Measure the resistance between the terminals.
 Replace the CDI unit if the readings are not       Black/ Yellow   Green
 within the specifications in the table below.
· Due to the semiconductor in circuit, it is
      necessary to use a specified tester for
      accurate testing. Use of an improper
      tester in an improper range may give
      false readings.
    · Use a Sanwa Electric Tester or Kowa
      Electric Tester (TH-5H).
    · In this table, "Needle swings then
      returns" indicates that there is a charging
      current applied to a condenser. The needle
      will then remain at "" unless the
      condenser is discharged.
                                                    Blue/ Yellow      Black/ Blue
 Use the x K range for the Sanwa Tester.
 Use the x 100 range for the Kowa Tester.

                                      Unit: K
    Probe
            Black/    Blue/   Green    Black/
 (-)Probe    Blue    Yellow            Yellow
  Black/
                              1~100      
   Blue
  Blue/
        100~                  1~100      
 Yellow

  Green     1~                           

 Black/
            1~100             0.1~50
 Yellow



                                                                                    15-10